Sepam series 20
Protection Relays for Standard or Usual Applications
Part of PowerLogic
Sepam series 20 offers 7 types of digital current or voltage protection for standard distribution systems, each one dedicated to a single application. Models available: Sepam S20, S24, T20, T24, M20, B21, B22.
Features
Sepam series 20 includes 7 types of Sepam. One type of Sepam is dedicated to one application.
Characteristics:
• 3 types of UMI
• 4 current inputs OR 4 voltage inputs
• 10 logic inputs
• 8 relay outputs
• 1 Modbus communication port
• 8 temperature sensor inputs
A ready to use Sepam series 20 includes :
• One base unit
• One 20 pin connector
• One current or voltage connector (depending on the application)
• One application
• One operating language
• Optional module(s) and/or optional communication interface(s)
• Optional core balance CT
Standard Manufacturers Warranty: 2 years
Benefits
Simplicity and performance, headed in the right direction
Protect your power system with full peace of mind using Sepam protection relays.
• 20 years of experience in digital relays
• A consistent range of relays organised according to applications
Applications
- Substation incomer and feeder protection: S20, S24
- Transformer protection: T20, T24
- Motor protection 2 voltage applications: M20
- Busbar protection: B21
- Loss of mains protections: B22
relay application | SUBSTATION | |
---|---|---|
range of product | Sepam series 20 | |
device short name | M20 | |
control and monitoring type | Circuit breaker/contactor control ANSI code: 94/69 (option) Latching/acknowledgement ANSI code: 86 Logic discrimination ANSI code: 68 (option) Switching of groups of settings Annunciation ANSI code: 30 | |
metering type | Phase current I1, I2, I3 RMS, residual current I0 Demand current I1, I2, I3, peak demand current IM1, IM2, IM3 Temperature (option) | |
network and machine diagnosis type | Unbalance ratio/negative sequence current Ii Disturbance recording Thermal capacity used Remaining operating time before overload tripping Waiting time after overload tripping Running hours counter/operating time Starting current and time Start inhibit time, number of starts before inhibition Tripping context | |
switchgear diagnosis type | Cumulative breaking current Trip circuit supervision (option) Number of operations, operating time charging time (option) |
type of measurement | Temperature Current | |
---|---|---|
protection type | Thermal overload protection ANSI code: 49RMS Temperature monitoring (8 RTDs) ANSI code: 38/49T (option) Phase undercurrent ANSI code: 37 Excessive starting time, locked rotor ANSI code: 48/51LR/14 Starts per hour ANSI code: 66 Phase overcurrent ANSI code: 50/51 Earth fault/sensitive earth fault ANSI code: 50N/51N Earth fault/sensitive earth fault ANSI code: 50G/51G Negative sequence/unbalance ANSI code: 46 | |
communication port protocol | Measurement readout ( option ) : Modbus Remote indication and time tagging of events ( option ) : Modbus Remote control orders ( option ) : Modbus Remote protection setting ( option ) : Modbus Transfer of disturbance recording data ( option ) : Modbus | |
input output max capacity | 10 inputs + 8 outputs | |
communication compatibility | IEC 60870-5-103 DNP3 Modbus RTU IEC 61850 | |
user machine interface type | Advanced Remote Without |